Click To Chat
Register ID Online
Login [Online Reload System]



Types of orifice meter

types of orifice meter Conical entry orifice plates The most commonly used flowmeter is the orifice meter. The center of the disk is drilled with a specific-size hole, depending on the expected fluid flow parameters (e. BS 1042 standard also provides the specifications for geometry and flow characteristics of integral orifice meters but there is not much research work done or information available on this type of orifice meters. Nov 10, 2018 · There are three major kinds of fittings as follows: Single Chamber. For example, a user who is willing to operate at differential pressures of 200 in. Complete assembly consists of an orifice plate, orifice flanges, bolts and gaskets along with valved tapping connections to differential […] Apr 17, 2019 · Orifice Performance. They are used for pipeline size from 1/2’’ (ND 15) until 1” 1/2’’ (ND 40). Mar 19, 2014 · In orifice flow meters, the pressure drop element is simply a flat plate metal with an orifice. It is a low cost device and having long life without regular maintenance. Meter run are used in small diameter pipelines, because of the roughness of the internai surface of pipe, that affect very much the coefficient of flow of the primary element. It restricts the flow and develops the Differential Pressure which is proportional to the square of the flow rate. Nov 25, 2016 · 6. orifice flow meter 1330L. The Orifice Carrier is supplied for applications where existing pipe-work has no facility for orifice tappings: when flanges are not of sufficient thickness, flanges are of composite design or pipes are lined preventing pipe taps. An orifice plate is a flate piece of metal with a restricted bore that is mounted between two orifice flanges for the purpose of flow measurement or is mounted between pair of standard flanges to restrict flow. To calculate the flowrate of a fluid passing through an orifice plate, enter the parameters below. It is usually placed in a pipe in which fluid flows. Differential pressure flow meters currently have the top market share for flow meter production volume. Jul 29, 2018 · Orifice plates and venturimeters come under the category of Variable head flow meters or Differential flow meters or Obstruction type meters. D and Orifice diameter through this formula. Size: DN50…600; up to PN100. The Primary Device: Orifice Plate: The orifice plate is basically a thin metal plate (1. 2 Specification Orifice Plate. Dual Chamber. This change can be used to measure the flowrate of the fluid. Venturi Tubes. are lined up to meet wide-ranging needs. Answer #2. It is installed in conjunction with downstream and upstream sections, and comes with O-ring Orifice Meter or Plate Types: Eccentric Orifice Plate:. Orifice plate flow meters provide data on the volumetric or mass flow rates of a fluid, based on the reading taken from the orifice plate. Orifice flow meter calibration helps reduce uncertainty in the discharge coefficient from 0. Tek-DP 1610B series includes weld neck, slip-on and threaded flange types to match your An orifice viscometer usually consists of a cup with a hole, through which the fluid flows. Three kinds of orifice plates are used: concentric, eccentric, and segmental (as shown in Figure 2). Its Working retort can be deliberate with excellence. Orifice plate can be supplies complete with ANSI B16. The orifice bore is positioned in the exact center of the plate. The orifice meter is sometimes called a pipe orifice, an end-cap orifice, or more descriptively, a circular orifice weir. 36 orifice flanges. The coefficient of the meter depends upon the position of taps. This specific type of orifice plates is used especially in air-conditioning or in industrial applications with rectangular or square sections of the conduits. Orifice metering satisfies most flow measurement applications and is the most common flow meter in use today. Sharp-edge orifice plates . Process Instrumentation Flow Measurement This is the most common type of flow meter used in process industry. (The default calculation involves air passing through a medium-sized orifice in a 4 Orifice plates with angular holes are specific types of throttling devices used for indirect measurement of air flow mass. The plate and handle are a one-piece seamless design on 1/8-in. Orifice plates are designed as per BS EN ISO 5187. of water column. 3 Venturi Flow meter The venturi flow meter, while considered an obstruction flow meter, is less of an obstruction than the orifice type. Jul 14, 2017 · By Pressure Drop, we can calculate the Flow rate base on the Ratio of Pipe I. Flow Measurement Excellence. The Orifice Meter, sometimes also called a head loss flow meter, is chosen most frequently because of its long history of use in many applications, versatility, and low cost, as compared to other available flow meter types. (The default calculation involves air passing through a medium-sized orifice in a 4 Orifice plate with annular chamber and corner taps. This is also the reason that the next flow meter type was developed. These flow meters measure system flow rate using, not surprisingly, an orifice plate. The FLOW ORIFICE TYPE METER RUN. Answer #3. 2 Orifice meter Figure 2 shows an orifice meter with the variable position of vena contracta with respect to the orifice plate. 17 different hole sizes are drilled in the stainless steel orifice plate. The flow calculations use a form of the Bernoulli equation with an empirical discharge coefficient. When measuring highly compressible gas-liquids or dense-phase fluids, an orifice flow meter measurement is less susceptible to errors, from variations in fluid densities due to changes in the operating conditions, compared to volume meters. The discharge coefficient of the restriction orifice plate is, as for the orifice plate, approximately 0. The major advantage of using these orifice flow meters is that they have no moving parts, require no lubrication or maintenance and the cost of Orifice Carriers. This meter comprises an Orifice Plate. This also work on the same principle as that of venturimeter. Solartron ISA is able to advise the most suitable flow measurement In line sizes from 2” and above, the orifice plate is one of the most common differential pressure type flow elements for the measurement of clean liquids, gases, and low-velocity steam flows. Orifice Plate Flow Meter. Mar 21, 2018 · Orifice is defined as the small opening on side or bottom of a tank through which any kind of fluid is flowing. it is a restriction element which creates the differential pressure. The flow measuring accuracy entirely depends upon the quality of Orifice plate, its installation and maintains. As shown in Fig-ure 1, they are the measurement orifice plate, which is in-stalled in the process line, and the differential pressure transmitter, which measures the pressure developed across the orifice plate. Description: The Madden Orifice Meter gives the boiler operator precise repeatable control of the continuous blowdown flow rate. it is of three types. They are generally used for those liquids which contains solids or gases. View product details. It is fixed concentric to pipe. By employing the continuity equation and Bernoulli’s principle, the volumetric flow rate through the orifice meter can be calculated as described previously for venturi meter. 6. The DP flowmeter is wet-calibrated and designed for use in small line sizes up to DN50 / 2” where the impact of certain An Orifice Flow Meter is a flow meter, generally used to measure the rate of flow of Liquid or Gas. 4404 / 316L. • Eccentric Orifice Plate. Although it is a simple device, the orifice plate flow meter is, in principle, a precision instrument. It can be used with differential pressure transmitters to measure various liquid or gas in the pipeline. The Sep 17, 2021 · There are various types of orifice plate used in orifice meter. Types of restriction orifice plates. It measures volumetric flow, though it can also calculate mass flow The most commonly used orifice plate for flow measurement is the square-edged, concentric bore orifice. Since Orifice plate can be installed directly to flange of pipe, flow measurement by this Orifice plate can be performed more economically than by orifice plates with rings, and it is generally suited for large diameter pipes. Also, the Reynolds number is a key factor in the orifice calculation, although if it doesn't vary much over the measurement flow range, you don't need to worry about it. The direct mount design In line sizes from 2” and above, the orifice plate is one of the most common differential pressure type flow elements for the measurement of clean liquids, gases, and low-velocity steam flows. It consists of an orifice plate with a pair of orifice flanges, which are tapped to receive sensing connections. Jul 29, 2018 · The main types includes: Orifice plate, Venturi, Dall, Rotameter, Gate meter, V-Cone, Nozzle, Target Meter and Giflo Element. Orifice Flow Meters: By measuring the pressure differential across a plate, this flow meter is efficient to measure the fluid flow through a pipe. Oct 28, 2020 · An orifice meter is essentially a thin circular plate with a sharp-edged concentric circular hole in it. industry-standard types and custom configured orifice plates to your requirements An orifice plate is a device used for measuring flow rate, for reducing pressure or for restricting flow (in the latter two cases it is often called a restriction plate). Orifice plates cover a wide range of application. Orifice plates are, however, quite sensitive to a variety of error-inducing conditions. The orifice meter consists of two parts. The upstream side of the orifice plate usually has a sharp, square edge facing into the flow Working Orifice meter is device used to determine the rate of flow through pipe. Each hole is precision drilled to a diameter that will produce the flow. • It consists of flat circular plate which has a circular hole, in concentric with the pipe. Sep 24, 2021 · The orifice plate is a natural gas flow meter type that determines flow by measuring pressure drop over an obstacle inserted in the flow pathway. It is used for robust applications as it is known for its durability and is economical. 3. Orifice flowmeter throttling device is used with differential Orifice type flow meter, also known as differential pressure flowmeter, is composed of primary detection part (throttle part) and secondary device (differential pressure transmitter and flow indicator), and is widely used in the flow of gas, steam and liquid. Fundamentally, an orifice meter provides volumetric flow rates of the fluid and by multiplying it with fluid density we can get mass flow rates. Using Bernoulli's principle, an orifice plate is installed into the path of flowing fluid, deliberately causing pressure loss. Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves. It is based on the same principle as explained in venturimeter. used in conjunction with orifice meters and accommodate an orifice plate holder for placing the orifice plate. 7% of rate as shown in the American Petroleum Institute (API) orifice meter standard (API 14. e. Using flange-taps is common, but the downstream flange tap is never at the location of the vena contracta, even though an orifice measurement depends on the downstream tap being located precisely at the vena contracta. Types Of Orifice Flow Meter We are ready to share our knowledge of marketing worldwide and recommend you suitable products at most aggressive costs. measuring. Orifice plate flow meter includes standard annular chamber orifice plate, nozzle and so on. • Our calibrations setups are designed as per ISA-RP16. Coriolis Flow Meters: In this, the flow of gas is measured by utilizing the density and velocity of the gas stream. In this article we look at Orifice Plate. 2. passed by the orifice and from that information engineers can then ascertain by mathematical algorithms what equations to use to duplicate those results. Orifice plates are the simplest and cheapest form of primary elements and are use more frequently than all other types. An orifice plate is inserted in the line and the differential pressure across it is measured. Flow Nozzles. The flange connection is of a RF type and the differential pressure tapping system is with flange taps. Flow meters are used in the industry to measure the volumetric ow rate of uids. Volumetric flow rate: 0 us gal/min - 43. The orifice meter is a flat plate with a circular hole that has pressure taps up and downstream form the orifice plate. rate indicator to the corner tap orifice. May 30, 2018 · The most common flow meter is a differential pressure meter consisting of an orifice with a concentric round hole machined to a specific value. orifice flow meter. 4. Orifice viscometers are easy to use manually, thanks to the fact that they’re simply dipped into the fluid being worked with — making them popular Jun 02, 2015 · Sizing. Paddle Orifice Plates are used with raised-face orifice flanges for measurement applications and installed between standard ASME flanges for restriction applications. Oct 07, 2021 · Orifice Meter – Process Data Sheet. g. Can select either digital indication or analog indication. Feb 04, 2021 · ORIFICE FLOWMETERS. In eccentric orifice plate the hole is off the center. With the use of Orifice Flow Meter, there is a reduced possibility of process fluid leakage. This creates a pressure drop across the orifice plate which varies with the flow rate, resulting in a differential pressure between the outlet and inlet segments. • Universal Orifice Plate. IT’S DESIGN Orifice meter is type of variable head meter. With an orifice plate, the fluid flow is measured through the difference in pressure from the upstream side to the downstream side of a partially obstructed pipe. Flow through a sharp-edged orifice plate is characterized by a change in velocity. 5 to 6 mm in thickness) with a hole bored in the centre. • Segmental Orifice Plate. 1330L. Types of Orifice Plates : • Square Edge Cocentric Orifice Plate. For orifice meter, the coefficient of discharge Cd depends on the shape of the nozzle, the ratio of pipe to nozzle diameter and the Reynolds A fluid passing though an orifice constriction will experience a drop in pressure across the orifice. Primary Element In orifice measurement there exists the Primary Mea-surement Element and the The Orifice Flow Meter is known for its stable long-term accuracy and repeatability. Orifice Plate and Orifice Meter Working/Types of Orifice Plates | Flow Measurement by Orifice Meter in Hindi - Orifice meter • Orifice meter: is a device used for measuring the rate of flow of a fluid flowing through a pipe. The calibrated orifice plate meter run with OPTIBAR DP 7060 is a DP flowmeter for volume flow measurement of liquids, gases and steam. thick orifice plates for line sizes 2-inch though 6 inch and ASME classes less than 900. It uses the principle of Differential Pressure Measurement. • Restriction Orifice Plate. Hence, ¥ 3= 8 6 5 6= Feb 02, 2012 · The most common types of differential pressure flowmeters are: Orifice Plates. A simple structure that attaches a flow. Viscosity is determined by timing how long it takes the cup to empty, and is measured in cup seconds. even for large bore. Below is a schematic of an orifice differential being compared to a known prover volume. (i) Single stage restriction orifice. An ori ce meter is a di erential pressure Orifice type flow meter, also known as differential pressure flowmeter, is composed of primary detection part (throttle part) and secondary device (differential pressure transmitter and flow indicator), and is widely used in the flow of gas, steam and liquid. An orifice meter is a conduit and a restriction to create a pressure drop. As shown, the orifice is equidistant (concentric) to the inside diameter of the pipe. It is used for measuring fluids who carry small amount of or gases with small amounts of Conical Orifice Plate:. The pressure di erence caused by the constriction is correlated to the ow rate using Bernoullis theorem. The pressure differential before and after the orifice plate is measured. Limitations Jun 26, 2020 · The Venturi meter can handle large range of flow rates of fluid than the Orifice meter but once the Venturi meter is installed the range of flow rates it can handle becomes fixed. Conic Edge orifice plate is useful for lower Reynolds numbers. It consists of an Orifice Plate which is the basic element of the instrument. Jan 30, 2021 · The price of the orifice meter is very low then other types of flow measurement instruments. 1 Description Orifice flange assemblies are used in conjunction with orifice plates for flow measurement of smaller or medium size pipes at lower or medium pressure ranges. Orifice flow meter. The orifice plate has a tab or printed label on one side where the specifications for the plate are stamped. Orifice Plate A orifice plate in its simplest form is a thin steel plate with a circular orifice of known dimensions located centrally in the plate. 1) concentric orifice plate. Different types of orifice plates . In this meter the obstruction to the flow consist of an engineering constriction in the metered fluid which causes a reduction in the flow pressure. Orifice Flow Meter . They are the Primary elements of differential flow meter. Orifice Meter with Prover Orifice Metering Flow Equations. A single stage restriction orifice is usually a plate or a block with a bore (orifice) sized to the intended permanent loss of pressure. Concentric orifice plates . of the system operations. 75-1. The orifice plate (orifice meter) is a differential pressure meter frequently used in natural gas measurement. points by over 50% and decrease start-up time due to the flexibility of numerous process connection options. 25%. There are four type of oriface plate. The Beta ratio is the ratio of the orifice size to the inside diameter of the pipe. Common types of positive displacement meters include reciprocating piston, rotating piston, nutating disk, sliding and rotating vanes, and gear and lobed impeller. 1. 5 Jan 2016 - Page 3 . Variable Area - Rotameters. Mar 27, 2017 · An orifice installation of this type used to be known as Class C, while if the orifice was installed in carriers with honed piping runs, that was called Class A. There has been extensive research to de Jun 01, 2009 · An orifice flow meter in liquid flow application can achieve precise flow rate measurement. Concentric orifice plates represent the majority of plates used in all orifice-based devices. Orifice meter size is determined largely by the range of differential pressures that are deemed acceptable to measure. It has a 45° bevel facing Segmental Orifice Plate:. The opening can be of circular, triangular or rectangular in cross section and they are named on the basis of shape accordingly. What is Orifice Meter? Orifice Meter (Orifice Plate): Definition, Types, Parts, Application, Working Principle, Components, Advantages & Disadvantages :- An orifice is defined as the device which is used for measuring the rate of Jan 05, 2016 · Orifice plate – overview – Rev. Most of these orifices are of the circular type, with the hole having a certain finish to its edge. Orifice type flow meter, also known as differential pressure flowmeter, is composed of primary detection part (throttle part) and secondary device (differential pressure transmitter and flow indicator), and is widely used in the flow of gas, steam and liquid. Under ideal conditions, the inaccuracy of an orifice plate can be in the range of 0. Nov 17, 2020 · Different Types of Natural Gas Flow Meter Measurement. There are in general four(4) methods of placing the taps. Four different types of differential pressure flow meters were studied which include: Venturi, standard concentric orifice plate, V-cone, and wedge flow meters shown in Fig. 1, 2,3-1959. This diagram shows how fluids flow through an orifice. . It uses the same principle as a Venturi nozzle, namely Jan 12, 2021 · Orifice Plate. it has a middle hole. The concentric orifice plate is the most common of the three types. Figure 1. Various types of flow rate indicators. Comparing the three types of flow meters discussed previously, we can conclude that the orifice plate has the highest energy loss due to the sudden contraction followed by the sudden expansion. The orifice provides the restriction to flow, while pressure taps on the upstream and downstream side of the restriction provide the necessary differential pressure. realizes superior cost performance. 5% to 0. As the name suggests, it consists of a single chamber designed for the precise measurement of the flow rate of a fluid or gas. orifice plate is a flow sensor device which is mostly used in the industries. 6 according to ISO 5167. The orifice diameter is generally kept half of the diameter of the pipe. The orifice plate type flow meter is a differential pressure device for measuring flow. It still does have a certain amount of pressure drop, but it is significantly less than the orifice type meter. 5% AR. Here is a description of a few common type of restriction orifice plate device used in Oil and Gas applications. The pressure drop across the Orifice accurate, economical measurement of process fluids. • It is a cheaper device as compared to venturimeter. the restriction orifice plate has a thickness of 3- 6 mm depending on the size of the tube. 3 [1]), which compares favorably to heavily calibrated turbine, ultrasonic and vortex meters. In the Orifice meter, the orifice plates can be easily removed and changed with a different orifice plate which contains different bore size or arrangement. Mar 01, 2020 · Concentric Orifice Plate (Hole is in the center) Eccentric Orifice Plate (Hole is off center) Segmental Orifice Plate. 6 Orifice flange assemblies, type: BLS-300 6. • Multistage Orifice Plate. On the other hand, the venturi meter has a lower energy loss compared with a flow nozzle because of the smooth, gradual reduction at the throat, followed by the smooth, gradual expansion after the throat. The orifice meter, sometimes called the head loss flow meter, is chosen most frequently because of its long history of use in many applications, versatility, and low cost, as Orifice Plate Flow Meter. An Orifice flow meter is the most common head type flow measuring device. Process temperature: 149 °C. Type: Orifice Plate Orifice meters measure flow rates using differential pressure created when a fluid passes through an orifice plate. So Profi Tools offer you finest benefit of money and we are ready to produce alongside one another with Types Of Orifice Flow Meter, Flowmeter Fuel , Nitrogen Flowmeter , Oxygen Flowmeter Regulator Oct 24, 2019 · Here, orifice meters have a mass flow rate uncertainty in the range of ±0. An orifice plate is a thin plate with a hole in the middle. C d is defined as the ratio of the actual flow and the ideal flow and is always less than one. The integral orifice meters are special type of obstruction type flow meters, which are used for small diameters and low flows. The reason behind this, is their low cost, easy installation and maintenance. A restriction fulfilling the function of a primary converter, is installed in a pipeline and produces in it a local change of a flow section. Orifice type flowmeters are widely used in our chemical process industries. With this design, the orifice bore is concentric with the internal walls of the pipe in which it is mounted, and the downsteam bore edge is bevelled to limit the plate edge thickness. Orifice. As for large diameter pipes of 500mm or greater, these Orifice plates are used to measure the • The Master Meters, which we use, are "Mage Flow Meters" Yokogawa Make having international tracebality certificate. Orifice plate flow meters, or simply orifice plates, are devices that are used to measure the rate of flow within a system. • We have orifice Calculation programes as pe BS1042 and ISI5167 The calibrated orifice plate meter run with OPTIBAR DP 7060 is a DP flowmeter for volume flow measurement of liquids, gases and steam. Temperature: up to +400°C / +752°F. and low-cost flow rate measurement. Additional bolts and screws facilitate sturdy flange connections and allow easy dismantling of flanges for plate inspection and replacement. , pressure and flow range). Orifice flow meters are used to determine a liquid or gas flow rate by measuring the differential pressure (P 1 - P 2) across the orifice plate. The orifice plate inserted in the pipeline causes an increase in flow velocity and a corresponding decrease in pressure. Also, this Orifice Flow Meter has a lower cost of installation than traditional orifice-type meters. An orifice plate may be considered as the simplest form of differential pressure flowmeter or flow restriction device. These type of meters require a straight section of pipe both upstream and downstream Basic Working Principle of an Orifice Meter The liquid or gas whose flow rate is to be determined is passed through the orifice plate. A fluid passing though an orifice constriction will experience a drop in pressure across the orifice. May 29, 2020 · Types of Fluid Flow Meters The differential pressure flow meter is based on the Bernoulli Equation where the pressure drop Orifice, Venturi, Flow Nozzles The orifice, nozzle and venturi flow rate meters use the for the venturi meter than for the orifice Meters Their Theory And Application The orifice meter is a differential pressure meter that uses an orifice element that is typically a thin, circular metal disk held between two flanges in the fluid stream. Orifice Plates. 2)Eccentric orifice plate. of water column would be able to flow more than 40% more gas through an identical device than a user who limits the differential pressure to 100 in. Fig. Di erential pressure type ow meters (Head ow meters) measure ow rate by introducing a constriction in the ow. Eccentric Orifice Plate. Orifice plate flow meters, also known as orifice plates, are a type of pressure-based flow meter. One type is the restriction orifice plate, which in construction and calculation follows the orifice plate, i. The two standard pressure tapping arrangements for small bore orifices are shown in the drawings; the location of the pressure taps affects the discharge coefficient somewhat. Use of an integral orifice flow meter will eliminate the three The integral orifice flow meter eliminates impulse lines, reducing leak measurement inaccuracies recorded in small orifice line installations. It can be installed at any position like horizontal vertical and tapper. meter type in use today. Orifice meters are usually circular orifices placed at the end of a horizontal discharge pipe as illustrated in Figure 1 Flow rates are calculated from the orifice characteristics and a measure of the pressure behind the Daniel™ Orifice Meter Tubes significantly minimize the adverse effects of turbulence on flow measurement accuracy by expertly combining a Daniel orifice fitting (Senior™, Junior™, Simplex™ or Orifice Flange Union) and a flow conditioner or tube bundle with the appropriate upstream and downstream pipe lengths based on end user requirements. Material: 1. The integral orifice is a flow element can be close -coupled with differential pressure transmitters to make a complete flow meter. The primary elements are placed in the path of the fluid and introduce an obstruction to the fluid passage in order to produce a differential Orifice type flow meter, also known as differential pressure flowmeter, is composed of primary detection part (throttle part) and secondary device (differential pressure transmitter and flow indicator), and is widely used in the flow of gas, steam and liquid. Principle of Operation. It features an inlet and outlet section to guarantee low-disturbance flow measurement. 8 us gal/min. Common types of flow elements are orifice plates, flow nozzles, venturi tubes, and averaging pitot tubes. Orifice Plate. It consist of flat circular plate which has a sharp edged circular hole called orifice. its shape same round of the plate. Differential pressure flow meters calculate flow by measuring pressure drop over an obstruction inserted in the flow path. What is an orifice define various types of an orifice? Orifice is defined as the small opening on side or bottom of a tank through which any kind of fluid is An Orifice Meter is a type of flow meter used to measure the rate of flow of Liquid in form of steam, using the Differential Pressure Measurement principle. The Venturi flow meter obtains a pressure differential by constricting the flow area and therefore increasing the velocity at the constriction, which creates a Ratio of orifice diameter to pipe diameter can be changed simply by installing a new orifice plate. Orifice meters are normally built to specification from standards such as Apr 12, 2021 · An orifice flowmeter will never be accurate and will become less accurate over time as the sharp edge of the orifice wears. It needs less space to work therefore it is the best choice for such applications where less space needs to work. When the Orifice Plate is placed in a line, a differential pressure is developed across the Orifice Plate. This type of flow meter provides data of the volumetric or mass flow rates of a fluid depending on the reading that is taken from the orifice plate. Concentric Orifice Plate. Measurement of the flow rates of liquids, gases and vapors with orifice meters has found wide use both in industrial and in scientific measurements. Others – such as Conical and Quadrant, and Edged Entrance types. for liquids in-line stainless steel. An orifice plate is inserted in the pipeline and the differential pressure across it is measured. In this type of orifice plate the hole is at the center. This is called Paddle Type Orifice Plates. Ratio of throat diameter to pipe diameter cannot be changed in Venturi Meter. Orifices are mainly used for measuring the rate of fluid flow. Orifice Plate is the heart of the Orifice Meter. types of orifice meter

arj hv7 cs2 8gv lwd k03 8fy 5yx yoe rkq iba wk6 fvi nya gmh add kxy oty rln roq